If there is too much interference and the system does not work reliably (many false alarms, piezo-siren beeps repeatedly), it is necessary to set parameters for difficult conditions:

  1. Transmitting mode trNo – SS4n, network synchronization 50(60) Hz
  2. Gain GAIn – Auto
  3. Delay Mode dENo – Auto
  4. Response rESP – SloU
  5. Sensitivity SEnS - SELo.

If the problem persists, set Delay Mode dENo – NAnU (manual network synchronization) and by tuning the Delay value (dEL4) try to reduce the interference.
If you did not manage to eliminate false alarms, set the Gain parameter to manual gain setting (GAIn – NAnU) and use Manual Gain 1, 2 (NAG1, NAG2) to reach operation without false alarms. Set the Transmitting mode to trNo – InFr (without network synchronization), set automatic gain adjustment (GAIn – Auto) and by changing the Internal Frequency (InFr) parameter try to reach operation without false alarms.