Difference between revisions of "Template:Setting and checking the operation of the counter"
From Awesome Baozam
(→You should check:) |
|||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
==Setting and checking the operation of the device== | ==Setting and checking the operation of the device== | ||
− | + | All Baozam devices have common interface for tuning via the Internet. | |
− | + | Please, read details at [[Device tuning via the baozam.net website]] page. | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
=== You should check: === | === You should check: === | ||
If the emitter beam hits the receiver sensors (parameters ''left sensor'' & ''right sensor''). | If the emitter beam hits the receiver sensors (parameters ''left sensor'' & ''right sensor''). | ||
− | * | + | * Switch on sensor monitors (''left sensor'', ''right sensor''). Normal values range 5 - 6. |
* If the reading is less than 5, the emitter and receiver are not aligned or something breaks the beam. Adjust the alignment, clean the beam path. | * If the reading is less than 5, the emitter and receiver are not aligned or something breaks the beam. Adjust the alignment, clean the beam path. | ||
* If values are greater than 7 look for the source of noise. | * If values are greater than 7 look for the source of noise. | ||
Line 15: | Line 11: | ||
The direction of the entrance/exit. | The direction of the entrance/exit. | ||
* By default, the input direction is from left to right relatively to the receiver. | * By default, the input direction is from left to right relatively to the receiver. | ||
− | * | + | * Switch on monitoring parameter ''count_in'' & ''count_out''. Break the beam ... |
* Change the direction by using the ''Mode Control'' button. Use the drop-down button ''LEFT to RIGHT is ENTER'' or ''LEFT to RIGHT is EXIT'' to select the desired direction. | * Change the direction by using the ''Mode Control'' button. Use the drop-down button ''LEFT to RIGHT is ENTER'' or ''LEFT to RIGHT is EXIT'' to select the desired direction. | ||
− | + | === Important!=== | |
+ | If you have changed any parameter, be sure to save the changes (''Settings'' --> ''Save''). Otherwise, when you switch the device off your settings will be lost. | ||
[[Category:PCounter]] | [[Category:PCounter]] |
Latest revision as of 12:15, 13 April 2017
Setting and checking the operation of the device
All Baozam devices have common interface for tuning via the Internet. Please, read details at Device tuning via the baozam.net website page.
You should check:
If the emitter beam hits the receiver sensors (parameters left sensor & right sensor).
- Switch on sensor monitors (left sensor, right sensor). Normal values range 5 - 6.
- If the reading is less than 5, the emitter and receiver are not aligned or something breaks the beam. Adjust the alignment, clean the beam path.
- If values are greater than 7 look for the source of noise.
The direction of the entrance/exit.
- By default, the input direction is from left to right relatively to the receiver.
- Switch on monitoring parameter count_in & count_out. Break the beam ...
- Change the direction by using the Mode Control button. Use the drop-down button LEFT to RIGHT is ENTER or LEFT to RIGHT is EXIT to select the desired direction.
Important!
If you have changed any parameter, be sure to save the changes (Settings --> Save). Otherwise, when you switch the device off your settings will be lost.