Difference between revisions of "EXTIN configuration v4"
Line 1: | Line 1: | ||
− | This parameters group allow to customize alarms detection via external in connector | + | The system has a external in connector (CON8) for alarm signals of third-party systems (RF/Acoustomagnetic EAS, other detectors). This functionality can provide alarms statistic acquisition and/or common indication usage. |
+ | |||
+ | This parameters group '|ExtIN' allow to customize alarms detection via external in connector . | ||
+ | |||
active mode enable | active mode enable |
Revision as of 16:14, 10 April 2018
The system has a external in connector (CON8) for alarm signals of third-party systems (RF/Acoustomagnetic EAS, other detectors). This functionality can provide alarms statistic acquisition and/or common indication usage.
This parameters group '|ExtIN' allow to customize alarms detection via external in connector .
active mode enable
Active mode switch to "High" or "Low" depended on input schematic.
Features: [0], [0, 1], [RWS].
time delay th [x10 ms]
It's a time delay after which external input changes consider as alarm.
Features: [100], [uint], [RWS].
alarm counter [extin]
Life time external in alarm counter.
Features: [var], [uint], [RW], [Stream, Monitor].
alarm time [extin]
Common time of alarms duty via external in.
Features: [var], [uint], [RW], [Stream, Monitor].
alarm state
Current alarm state via external in.
Features: [var], [0, 1], [RW], [Stream, Monitor].