EXTIN configuration v4

From Awesome Baozam
Revision as of 16:16, 10 April 2018 by Ypypy (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

The system has a external in connector (CON8) for alarm signals of third-party systems (RF/Acoustomagnetic EAS, other detectors). This functionality can provide alarms statistic acquisition and/or common indication usage.

This parameters group ExtIN allow to customize alarms detection via external in connector .


  • active mode enable - active mode switch to "High" or "Low" depended on input schematic. Features: [0], [0, 1], [RWS].
  • time delay th - [x10 ms] It's a time delay after which external input changes consider as alarm. Features: [100], [uint], [RWS].
  • alarm counter [extin] - life time external in alarm counter. Features: [var], [uint], [RW], [Stream, Monitor].
  • alarm time [extin] - common time of alarms duty via external in. Features: [var], [uint], [RW], [Stream, Monitor].
  • alarm state - current alarm state via external in. Features: [var], [0, 1], [RW], [Stream, Monitor].