User contributions
(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)
- 16:47, 24 November 2018 (diff | hist) . . (+747) . . N MagnetGuard V2 - The Central Unit (Created page with "== The central unit == The '''central unit''' (see figure) can be paired wireless with up to ten sensors and informs us with light and/or sound alarms about detacher/magnet de...")
- 16:43, 24 November 2018 (diff | hist) . . (+4) . . MagnetGuard V2 - General installation issues (→Installation guidelines for optimum performance)
- 16:43, 24 November 2018 (diff | hist) . . (+4) . . MagnetGuard V2 - General installation issues (→Noise sources)
- 16:41, 24 November 2018 (diff | hist) . . (+9) . . MagnetGuard V2 - General installation issues (→Installation guidelines for optimum performance)
- 16:40, 24 November 2018 (diff | hist) . . (+2) . . MagnetGuard V2 - General installation issues (→Noise sources)
- 16:40, 24 November 2018 (diff | hist) . . (+1,819) . . N MagnetGuard V2 - General installation issues (Created page with "== General installation issues == =Noise sources= The list below shows possible noise sources:<br> :-moving objects containing metal (sliding doors, elevators, cash machines,...")
- 16:32, 24 November 2018 (diff | hist) . . (+364) . . Magnet detector (→Installation)
- 16:28, 24 November 2018 (diff | hist) . . (+102) . . Magnet detector
- 16:18, 24 November 2018 (diff | hist) . . (-349) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters (→Setting the Delay value parameter – dEL4) (current)
- 16:16, 24 November 2018 (diff | hist) . . (+51) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters (→Setting the Internal Frequency parameter – InFr)
- 16:15, 24 November 2018 (diff | hist) . . (+66) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters (→Setting the Advertisement parameter – AduE)
- 16:07, 24 November 2018 (diff | hist) . . (+39) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters (→Setting the Relay time parameter – r t1)
- 16:05, 24 November 2018 (diff | hist) . . (+29) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters (→Setting the Sound volume parameter – S uL)
- 16:03, 24 November 2018 (diff | hist) . . (+47) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters (→Setting the Sound time parameter – S t1)
- 16:02, 24 November 2018 (diff | hist) . . (+39) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters (→Setting the Sound repeat parameter – S rP)
- 15:54, 24 November 2018 (diff | hist) . . (-3) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters
- 15:48, 24 November 2018 (diff | hist) . . (+157) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters
- 15:41, 24 November 2018 (diff | hist) . . (+16,343) . . Iridium mono 2k IR 1040 06 V4 - Setting the parameters
- 15:15, 24 November 2018 (diff | hist) . . (+1,184) . . N Iridium mono 2k IR 1040 06 V4 - Setting the parameters (Created page with "== Setting the parameters == The following parameters can be set on the electronics: {|border=1 cellpadding=5 |- | 1 || NodE || Mode || (Mode of operation) |- | 2 || trNo || T...")
- 15:02, 24 November 2018 (diff | hist) . . (+1,656) . . N Iridium mono 2k IR 1040 06 V4 - Description of measured data control (Created page with "The control of measured data is the default display mode. In this mode, the serial number of the displayed data is displayed for about a second, then the data value is display...") (current)
(newest | oldest) View (newer 20 | older 20) (20 | 50 | 100 | 250 | 500)